Grafting Eyelash Glue Fresh Series

Low whitening phenomenon; Glue has strong weather resistance and little environmental impact.

Compare
Categories: ,
Share this product

Description

NO. Product
name
coposition viscosity
(cps)
Drying time(sec) Available  time (min) Lasting time (week) spec. Color characteristic
Flexibility / Impact Resistance Hypoalbinism
1 K191 Alkoxyl/
Ethyl
155~175 <1 45 6~7 5g,10g Grayish black ««« «««
2 K192 Alkoxyl/
Ethyl
145~165 1 45 6~7 5g,10g Grayish black ««« «««
3 K193 Ethyl 155~175 1 45 5~6 5g,10g Grayish black «« ««
4 K194 Ethyl 135~155 <1 45 5~6 5g,10g Cyan black «« ««
5 K195 Ethyl 120~140 2 45 5~6 5g,10g Cyan black «« ««
6 K196 Ethyl 120~140 3 45 5~6 5g,10g Cyan black «« ««
7 K182 Ethyl 120~140 1~2 45 6~7 5g,10g Grayish black «« ««
8 K182P Ethyl 110~130 1 45 6~7 5g,10g Grayish black «« ««
9 K183 Ethyl 120~140 2~3 45 6~7 5g,10g Grayish black «« ««
9 K183P Ethyl 120~140 2 45 6~7 5g,10g Grayish black «« ««
10 K168 Ethyl 140~160 1~2 45 6~7 5g,10g Grayish black «« ««
11 K169 Ethyl 130~150 2 45 6~7 5g,10g Grayish black «« ««
12 K155 Ethyl 145~165 1~2 45 6~7 5g,10g Grayish black «« ««
13 K145P Ethyl 135~155 1 45 6~7 5g,10g Grayish black «« ««
14 K153 Alkoxyl 190~210 8~9 45 3 5g,10g Grayish black «« ««
[Test condition]
1. viscosity : Brookfield analogue Viscometer (LVL type) , 62rotor, 60rpm (@25℃±2℃)
2. drying time : The time of initial adhesion during grafting (@25℃±2℃, 45~65%RH)
3. Available time :  Test the viscosity rise time after the glue drops to the dispenser ( (@25℃±2℃, 45~65RH)[Notes]
[Notes]
1. viscosity varies with temperature, especially in winter when the temperature is low,the viscosity will rise,The viscosity will return to normal after being placed at room temperature of  (@25℃±2℃ for 2~3hr.
2. the time in the curing time is used as the reference when choosing glue,The actual operation of the glue viscosity due to temperature and humidity will have some differences some differences
3. If the glue exceeds the available time range after pouring, it may affect the curing time and the duration of the eyelash grafting.
4.  Apply a raincoat to the grafted lashes once a day for longer lash duration (raincoat: waterproof and oil resistant).
[Product Ingredients] Ethyl cyanoacrylate, acrylic polymer, carbon black
[Product principle] The water molecules on the surface of the material react with the acidic stabilizer in the monomer, so that the monomer in the glue polymerizes to form a glue chain, and the glue chain is superimposed to realize curing, thus completing the bonding with the real eyelashes.
[Product parameters] *
Viscosity (CPS) of 120-140
Duration (week) 5 ~ 6
Curing time (sec) 2
Opening hours (minutes) * * 45
VOC(ppm) 4.216
TVOC(ppm)*** 18.14
Extension length (mm) 5.093
Strength (Newton) 1.081
[Key Features] Fast grafting speed
[Product Advantage] Low whitening phenomenon; Glue has strong weather resistance and little environmental impact.
[Application] It is more suitable for grafting the following types of false eyelashes: single eyelashes, multiple hairs, V-shaped eyelashes, and flowering eyelashes.
[usage method] 1. Temperature and humidity. It is suggested that the ideal operating environment is air temperature of 25℃ 2℃ and humidity of 50 5% RH;
2. Shake the glue thoroughly before grafting;
3. After each glue drop, dry the bottle mouth with non-woven fabric, and then tighten the bottle cap;
4. Before grafting, it needs to be cleaned: glue-dripping auxiliary materials, bonded real eyelashes and false eyelashes.
“Specifications” 5g, 10g, customizable
[color] black and blue
[Packaging and Transportation] Please choose polyethylene plastic material as the container, with desiccant, and choose the anti-collision packaging during transportation to reduce damage.
[storage method] 1. Before opening, store at a low temperature. The recommended storage temperature is 2-8℃; After opening, store at room temperature;
2. After opening, store it in a closed condition, and reduce air contact to keep the best performance of the product;
3. Avoid light and direct sunlight;
4. Store away from ammonia compounds.
[Waste disposal] After being completely cured, glue can be treated together with plastic waste or domestic waste; Uncured glue and containers containing glue are classified as hazardous wastes. Please dispose of them according to your local regulations.
[Shelf life] 6 months before opening, within 3 months after opening.
[Precautions] 1. Please use it according to the product characteristics, and do not use it for other purposes;
2. Please install a ventilation system in the grafting environment;
3. Please keep this product out of the reach of children;
4. Avoid contact with skin and eyes during grafting. In case of glue entering the eyes, please keep your eyelids open, rinse with plenty of water and seek medical advice in time;
5. If skin adhesion occurs during grafting, please rinse with plenty of water and seek medical attention in time; Please refer to MSDS for more notes.

EN/JP